Step sheathing can then be applied over the solid sheathing as needed.
Roof sheathihng air flow corrupated.
Insert a strip vent or other vents in the new soffit to ventilate the attic and roof.
If the roofing is tight to the sheathing there is no air to vent no condensation to dissipate.
Use cardboard or plastic baffles opening photo to keep your insulation from blocking the airflow.
More recently however most roofers recommend solid sheathing on the roof to give the house additional resistance to movement or shear strength.
Using a thin nylon matrix profile cedair mat prolongs the life of the roof structure and membrane by reducing the adverse effects associated with moisture water damage including mold mildew corrosion and deterioration of the roofing material itself.
This ventilation offers another benefit.
The 90 open mesh creates an airspace cavity that is perfect for promoting air flow in all directions between the metal panels and sheathing.
Cedair mat is a roof ventilation mat designed to create an airspace cavity to promote air flow in all directions between the roofing material and the sheathing below.
Full insulation coverage accuvent allows insulation to be packed out over the top plate and keeps it in place preventing the insulation from drifting into the soffit openings.
The added strip vent allows plenty of air to flow into the attic and out through other vents located near the peak of the roof.
Once you have provided a drainage path you now have to reinvent how the eaves are detailed as your path runs below the roofing.
If there is a leak the air flow ventilation will help dry out the moisture.
Where the roof sheathing.
Allowing air to flow in and out of the attic space protects roof shingles and prevents moisture buildup and mold growth improving overall energy efficiency of the home.
In winter the natural convection air flow through the attic prevents ice dams.
The super heated air inside the attic can warp and damage roof shingles if not forced out through gable or roof vents.
Shingles which must permit air to circulate under them are now often placed on a special membrane that permits circulation.
R vent is a 40 recycled ventilation mat used in cedar metal tile roof construction.
The 90 open mesh creates an airspace cavity that is perfect for promoting air flow in all directions between the metal panels and sheathing.
Fasteners for asphalt shingles shall be galvanized stainless steel aluminum or copper roofing nails minimum 12 gage 0 105 inch 2 67 mm shank with a minimum 3 8 inch diameter 9 5 mm head of a length to penetrate through the roofing materials and a minimum of 3 4 inch 19 1 mm into the roof sheathing.